Knowledge · Test Reports

How to Read a Flooring Test Report

A test report is evidence about one product construction, tested on one date, against one edition of one standard. This page explains which fields matter, how to verify a report number, and where the limits of a report lie.

What a report does — and does not — tell you

A test report records that a specific construction was tested by a named laboratory on a stated date against a stated standard. It is evidence, not a general certificate of quality: it does not cover products other than the one tested, and it does not on its own prove suitability for a particular building.

  • It covers the tested construction — the product type, thickness, wear layer and backing stated on the report.
  • It points to one edition of a standard — a report to an earlier edition of a standard documents an earlier test.
  • It says nothing about installation quality — substrate preparation and workmanship are covered by site practice and the installation standard.

The fields that matter

FieldWhat it tells youWhat to check
Report numberThe issuing laboratory's unique identifier for the documentQuote it verbatim in the specification and order
Test standard and clauseWhich method was used, and which editionMatch it to the clause in your tender
Product identificationProduct type, thickness, wear layer, backingCompare with what is being supplied — a different thickness is a different construction
Result or classificationThe measured value or classCompare with the requirement, not with a competitor's figure
Test date and laboratoryWhen the test was performed and who signed itCheck the laboratory and the date on the report

Reading our reports

TestStandardResultReport number
Reaction to fire — homogeneous vinyl sheetEN 13501-1:2018Class Bfl-s1260709013SHF-006
Reaction to fire — heterogeneous vinyl sheetEN 13501-1:2018Class Bfl-s1260709013SHF-002
Fungal resistanceASTM G21-15 (2021)Rating 0260709013SHF-007 / 260709013SHF-004
Physical and chemical propertiesISO 23999:2025 and relatedSee report260709013SHF-005 / 260709013SHF-001
RoHSSGS, EU 2015/863CompliantSHAPH26027982201

Three checks before you accept a report

  • The number is quoted verbatim — in the specification, the quotation and the final documentation, so the same document can be traced later.
  • The product matches — thickness, wear layer and backing must correspond to what is actually being supplied.
  • The standard edition matches — your tender may cite a specific edition, and a report to an earlier edition documents an earlier test.

Our reports, with their numbers, are published on the test reports page so they can be checked against the laboratory's records. For the order and sampling sequence behind a project, see the ordering and sampling process.

Frequently asked questions

What is a report number, and why does it matter?

It is the issuing laboratory's unique identifier for that document. Quoting it verbatim in the specification and order documentation lets anyone trace which report covers the material supplied.

Can I verify a report with the issuing laboratory?

You can ask the laboratory to confirm the report number. Where a laboratory confirms only to the commissioning party, we provide the report file directly.

Does one report cover every colour, thickness and format?

No. A report covers the construction that was tested — as a rule one product type, thickness, wear layer and backing. A different thickness or backing is a different construction and is not covered by that report.

How long is a test report valid?

A report documents a test performed on a date against an edition of a standard. There is no universal expiry: what matters is whether the cited edition and the tested construction still match your requirement.

Need Documentation for Your Project?

Send us your specification and we will provide the matching test reports and product data.